Brueninghaus axial piston unit A10VO 28 - 140 series 31

 Go to series 52/53

 

The different sizes of the Brueninghaus hydraulic pump A10VO:

  • A10VO 28
  • A10VO 45
  • A10VO 71
  • A10VO 100
  • A10VO 140

 

The different control devices of the Brueninghaus hydraulic pump A10VO 28 - 140 at a glance:

DG = Two point control, directly operated
DR = Pressure control
DFR = Pressure control with flow control, hydraulic, X – T open
DFR1 = Pressure control with flow control, hydraulic, X – T closed
EF = Pressure control with flow and differential pressure control, electrically variable
DRG = Pressure control with pressure cut-off, remotely operated, hydraulic
ED71 = Pressure control w. pressure cut-off, remotely op., electrical, negative characteristic 12 V
ED72 = Pressure control w. pressure cut-off, remotely op., electrical, negative characteristic 24 V
ER71 = Pressure control w. pressure cut-off, remotely operated, electrical, positive characteristic 12 V
ER72 = Pressure control w. pressure cut-off, remotely operated, electrical, positive characteristic 24 V
DFLR = Pressure, flow and power control

 

Ordering code example:

A10V | O | 28 | DG | 31 | R | V | S | C | 12 | N00

 

Ordering code for standard program:

A10V = Axial piston unit
O = Operation mode
28 = Size
DG = Control device
31 = Series
R = Direction of rotation
V = Seals
S = Drive shaft
C = Mounting flange
12 = Service line ports
N00 = Through drive

 

Brueninghaus axial piston pump A10VO 18-100 series 52 / 53

Go to series 31

 

 The different sizes of the Brueninghaus hydraulic pump A10VO series 52 / 53:

  • A10VO 18
  • A10VO 28
  • A10VO 45
  • A10VO 60
  • A10VO 63
  • A10VO 85
  • A10VO 100

 

The different control devices of the Brueninghaus hydraulic pump A10VO series 52 / 53 at a glance:

 

DR = Pressure control

Pressure control with flow control
DFR = hydraulic, X - T open
DRF = hydraulic, X - T open
DFR1 = hydraulic, X - T closed
DRS = hydraulic, X - T closed
EF.D. = hydraulic, electrically overridable (negative characteristic)

Remote-controlled pressure regulator with pressure
DRG = hydraulic
ED71 = with pressure cut-off, remotely operated, electrical, negative characteristic 12 V
ED72 = with pressure cut-off, remotely operated, electrical, negative characteristic 24 V
ER71 = with pressure cut-off, remotely operated, electrical, positive characteristic 12 V
ER72 = with pressure cut-off, remotely operated, electrical, positive characteristic 24 V

Power control with pressure
LA5D = beginn of regulation 10 bis 35 bar
LA6D = beginn of regulation 36 bis 70 bar
LA7D = beginn of regulation 71 bis 105 bar
LA8D = beginn of regulation 106 bis 140 bar
LA9D = beginn of regulation 141 bis 230 bar
LA.DG = remote-controlles, beginn of regulation see LA.D
LA.DS = flow rate control, X – T closed, beginn of regulation see LA.D
LA.S = flow rate control, electrically overridable (negative characteristic), X – T closed, begin of regulation see LA.D

Electro-proportional control (positive characteristic) with
EP1D = pressure control, U = 12 V
EP2D = pressure control, U = 24 V
EP1DF = pressure and flow control, X - T open (load sensing) U = 12 V
EP2DF = pressure and flow control, X - T open (load sensing) U = 24 V
EP1DS = pressure and flow control, X - T plugged (load sensing) U = 12 V
EP2DS = pressure and flow control, X - T plugged (load sensing) U = 24 V
EP1ED = electrohydraulic pressure control, U = 12 V
EP2ED = electrohydraulic pressure control, U = 24 V
EK1DF = pressure and flow control with controller cut-off, X - T open (load sensing) U = 12 V
EK2DF = pressure and flow control with controller cut-off, X - T open (load sensing) U = 24 V
EK1DS = pressure and flow control with controller cut-off, X - T plugged (load sensing) U = 12 V
EK2DS = pressure and flow control with controller cut-off, X - T plugged (load sensing) U = 24 V
EK1ED = electrohydraulic pressure control with controller cut-off, U = 12 V
EK2ED = electrohydraulic pressure control with controller cut-off, U = 24 V

 

Ordering code example:

A10V | O | 18 | DR | 52 | R | V | S

 

Ordering code for standard program:

A10V = Axial piston unit
O = Operation mode
18 = Size
DR = Control device
52 = Series
R = Direction of rotation
V = Seals
S = Drive shaft

 

We would be pleased to maintain your hydraulic units.


Kastaun
Sascha Kastaun,
Vânzări Internationale

Telefon: +49 201.8 58 13-27
E-Mail: kastaun@hk-hydraulik.de
Contact

Langenberger Str. 436
45277 Essen
Germany

 

 

Um Ihnen ein optimales Nutzererlebnis zu bieten, verwenden wir technisch erforderliche Cookies. Durch Nutzung unserer Internetseiten erklären Sie sich damit einverstanden.

Unsere Datenschutzerklärung finden Sie hier.