Brueninghaus axial piston unit A10VO 28 - 140 series 31

 Go to series 52/53

 

The different sizes of the Brueninghaus hydraulic pumpHydraulic pumps convert mechanical energy into hydraulic energy (or vice versa). As a rule, the pump draws the pressurised fluid from a storage tank and conveys it to the pump outlet. From here, it is conducted via valves to cylinders or hydromotors (load consumers) and back to the storage tank. A10VO:

  • A10VO 28
  • A10VO 45
  • A10VO 71
  • A10VO 100
  • A10VO 140

 

The different control devices of the Brueninghaus hydraulicThe use of liquids to transmit force and energy. pump A10VO 28 - 140 at a glance:

DG = Two point control, directly operated
DR = Pressure control
DFR = Pressure control with flow control, hydraulic, X – T open
DFR1 = Pressure control with flow control, hydraulic, X – T closed
EF = Pressure control with flow and differential pressureDescribes the difference between the input and output pressures measures under certain conditions control, electrically variable
DRG = Pressure control with pressure cut-off, remotely operated, hydraulic
ED71 = Pressure control w. pressure cut-off, remotely op., electrical, negative characteristic 12 V
ED72 = Pressure control w. pressure cut-off, remotely op., electrical, negative characteristic 24 V
ER71 = Pressure control w. pressure cut-off, remotely operated, electrical, positive characteristic 12 V
ER72 = Pressure control w. pressure cut-off, remotely operated, electrical, positive characteristic 24 V
DFLR = Pressure, flow and power control

 

Ordering code example:

A10V | O | 28 | DG | 31 | R | V | S | C | 12 | N00

 

Ordering code for standard program:

A10V = Axial piston unit
O = Operation mode
28 = Size
DG = Control device
31 = Series
R = Direction of rotation
V = Seals
S = Drive shaft
C = Mounting flange
12 = Service line ports
N00 = Through drive

 

Brueninghaus axial piston unit A10VO 18-100 series 52 / 53

Go to series 31

 

 The different sizes of the Brueninghaus hydraulic pump A10VO series 52 / 53:

  • A10VO 18
  • A10VO 28
  • A10VO 45
  • A10VO 60
  • A10VO 63
  • A10VO 85
  • A10VO 100

 

The different control devices of the Brueninghaus hydraulic pump A10VO series 52 / 53 at a glance:

 

DR = Pressure control

Pressure control with flow control
DFR = hydraulic, X - T open
DRF = hydraulic, X - T open
DFR1 = hydraulic, X - T closed
DRS = hydraulic, X - T closed
EF.D. = hydraulic, electrically overridable (negative characteristic)

Remote-controlled pressure regulator with pressure
DRG = hydraulic
ED71 = with pressure cut-off, remotely operated, electrical, negative characteristic 12 V
ED72 = with pressure cut-off, remotely operated, electrical, negative characteristic 24 V
ER71 = with pressure cut-off, remotely operated, electrical, positive characteristic 12 V
ER72 = with pressure cut-off, remotely operated, electrical, positive characteristic 24 V

Power control with pressure
LA5D = beginn of regulation 10 bis 35 bar
LA6D = beginn of regulation 36 bis 70 bar
LA7D = beginn of regulation 71 bis 105 bar
LA8D = beginn of regulation 106 bis 140 bar
LA9D = beginn of regulation 141 bis 230 bar
LA.DG = remote-controlles, beginn of regulation see LA.D
LA.DS = flow rate control, X – T closed, beginn of regulation see LA.D
LA.S = flow rate control, electrically overridable (negative characteristic), X – T closed, begin of regulation see LA.D

Electro-proportional control (positive characteristic) with
EP1D = pressure control, U = 12 V
EP2D = pressure control, U = 24 V
EP1DF = pressure and flow control, X - T open (load sensing) U = 12 V
EP2DF = pressure and flow control, X - T open (load sensing) U = 24 V
EP1DS = pressure and flow control, X - T plugged (load sensing) U = 12 V
EP2DS = pressure and flow control, X - T plugged (load sensing) U = 24 V
EP1ED = electrohydraulic pressure control, U = 12 V
EP2ED = electrohydraulic pressure control, U = 24 V
EK1DF = pressure and flow control with controller cut-off, X - T open (load sensing) U = 12 V
EK2DF = pressure and flow control with controller cut-off, X - T open (load sensing) U = 24 V
EK1DS = pressure and flow control with controller cut-off, X - T plugged (load sensing) U = 12 V
EK2DS = pressure and flow control with controller cut-off, X - T plugged (load sensing) U = 24 V
EK1ED = electrohydraulic pressure control with controller cut-off, U = 12 V
EK2ED = electrohydraulic pressure control with controller cut-off, U = 24 V

 

Ordering code example:

A10V | O | 18 | DR | 52 | R | V | S

 

Ordering code for standard program:

A10V = Axial piston unit
O = Operation mode
18 = Size
DR = Control device
52 = Series
R = Direction of rotation
V = Seals
S = Drive shaft

 